Ten best practices for a green IT system

Ten best practices for a green IT system

Posted by r.meneses
These best practices were developed within the RVO Energy Footprint Project, supported by the Knowledge Network Green Software (KNGS) and the Cluster Green Software.
 

Ten best practices for a green IT system

 

1. Use a virtualised environment where possible

Footprint measurements clearly show that a virtual server is ten times more energy efficient than a physical server. The superfluous capacity of the server can be used by other applications. When creating the architecture of an application, bear in mind that all parts will be virtualised.

2. Make use of the energy efficiency settings offered by the hardware and virtualisation layer

Energy footprint measurements show that the use of energy-efficient hardware settings (for example, using CPU C-states) is not trivial in deployed servers and other hardware in the data centre. Even “pre-tuned variables” are changed to less energy-efficient settings without considering the consequences.

3.Provide a measurement infrastructure for determining energy KPIs during the rollout of the application in its production environment

Turning on energy measurements afterwards is not cost-effective and is often difficult. The availability of energy measurements is imperative for checking the energy efficiency of applications.

4. Dare to consider approaches that lead to more energy effective solutions

The trends and effects of changes to the system can become apparent by using the measurement infrastructure. In many situations, the operations team is afraid to make changes and as a consequence energy inefficient situations persist. Lower energy efficiency comes to light if the system is experimented with and explored from the beginning, when knowledge about the system is still ‘fresh’. Share the knowledge about the system among the teams, including the operations team.

5. Replace older hardware with new hardware

Older hardware (more than three years old) is less efficient than the latest hardware. The capacity and processing power of hardware (and software) improves every year. By postponing replacement, energy inefficient situations may continue to exist.

6. Limit the oversizing of systems

Projects and systems often need several years before the projected load on the systems is reached. During the first period of deployment, significant oversizing may occur. This is not a desirable situation, since the system is often not used in an efficient manner during this period. This situation can be prevented by not initially sizing the system according to its final dimensions; instead gradually increase its capacity. Redundant capacity should be released for other applications’ use.

7. Reconsider availability requirements

Application owners tend to exaggerate the availability requirements to create safety margins for their application. Very often the requirements prove not to be realistic; however the infrastructure has already been delivered and is operational. In such cases it is necessary to have a process to reconsider the requirements. The software under investigation must support the possible outcomes (use less hardware/capacity).

8. Only activate the test and failover environment when needed

Configure the test and failover environment so that they are only switched on when they are actually needed. It is common for testing and disaster recovery environments to be left on continuously. Acceptance environments are only used during new release testing. Make starting and stopping a test and disaster recovery environment relatively simple.

9. Optimise for performance

Performance optimisations, like improving hardware resource consumption (CPU/memory etc.) relative to the amount of work (transactions), often lead to a reduction in energy consumption. A lot of tooling and experience is available for performance analysis, so use it! An environment is often sized based on its peak load. Increasing the capacity while using the same hardware can have a big effect on the energy-efficiency.

10. Take the workload pattern into account when sizing the system

Many systems show a pattern in the workload: a constant load or a peak once a day, week, month or year. Determine the anticipated workload and design the system in such a way that it can handle the variation. In a system with a constant load, less spare capacity is needed to cope with the variation. If a system shows an annual peak in its load, the system can be scaled down during the rest of the year.

Credits by SIG - Software Improvement Group (Source here)

Want to improve your energy efficiency? Visit our Services page to see how ICTFOOTPRINT.eu can help you.

european commission© 2018 ICTFOOTPRINT.eu – ICTFOOTPRINT.eu has received funding from the European Commission’s Horizon 2020 research and innovation programme under the Grant Agreement no 690911. The content of this website does not represent the opinion of the European Commission, and the European Commission is not responsible for any use that might be made of such content.
Privacy Policy | Disclaimer Terms of use

Ten best practices for a green IT system | ICTFOOTPRINT.eu

Error

Error message

  • Unable to send e-mail. Contact the site administrator if the problem persists.
  • Warning: Cannot modify header information - headers already sent by (output started at /var/www/html/web/includes/common.inc:2861) in drupal_send_headers() (line 1554 of /var/www/html/web/includes/bootstrap.inc).
  • Error: Call to undefined function imap_open() in support_client_fetch() (line 3611 of /var/www/html/web/sites/all/modules/contrib/support/support.module).
The website encountered an unexpected error. Please try again later.